Showing results: 1951 - 1965 of 2756 items found.
-
Osborne Transformer Corp.
Osborne Potential Transformers (PT’s) are used to reduce higher system voltages to lower values that are appropriate for instrumentation and/or protection circuits. They have been designed to meet specified current ratios, and burden impedance at a specified transformation error. One area of unique Osborne expertise is in designing for phase shift when potential transformers are to be used for power measuring applications.
-
Ascent XV -
Real Intent, Inc.
The Ascent X-design and verification system (XV) prevents, detects and isolates issues caused by the propagation of unknowns (‘Xs’) in RTL designs, including Xs that occur during power-on initialization and switching between power modes. Early sign-off of X issues eliminates costly, painful gate-level debug, and prevents hidden functional bugs from slipping through to silicon.
-
W-IE-NE-R, Plein & Baus GmbH
WIENER presents with Mpod a new, universal multi-channel low voltage (LV) and high voltage (HV) computer controlled power supply system. Offering highest channel density the MPOD mainframe can house up to 10 plug-in modules which can be mixed in type and parameters. Up to 80 individually controlled low voltage channels are available in one mainframe
-
W-IE-NE-R, Plein & Baus GmbH
WIENER presents with Mpod a new, universal multi-channel low voltage (LV) and high voltage (HV) computer controlled power supply system. Offering highest channel density the MPOD mainframe can house up to 10 plug-in modules which can be mixed in type and parameters. Up to 480 individually controlled high voltage channels are available in one mainframe
-
Rockwell Automation
Manage your manufacturing processes by integrating the critical data from your shop-floor with enterprise IT and other manufacturing applications. Think of the power. FactoryTalk® Transaction Manager can take an industrial transaction and tightly link it to multiple systems so they act as one. This helps you establish an end-to-end link, giving you reliability to support enterprise-wide integration.
-
SG5201 -
Shanghai Jiuzhi Electric Co., Ltd.
This instrument offers a complete set of functions to measure and detect effectively all parts of current in an insulation system. The instrument can supply an output power of 5W and a test voltage of up to 5000V and therefore measure insulation resistances up to 1TOhm. Additionally step-up voltage measurement, withstand voltage measurement, AC/DC voltage and frequency measurements up to 600V can be performed.
-
HWA4100 (With SNMP) -
Hangzhou Huatai Optic Tech. Co., Ltd.
Huatai HWA4100 series, is designed for C-Band 44 waves or 88 waves DWDM system design power fiber amplifier gain flatness. Products using the most excellent optical performance, the most advanced electronic control technology and comprehensive software features, has a wide operating wavelength range, low noise and excellent gain flatness characteristics.
-
Elmeasure India Pvt. Ltd
Real time monitoring and reportingComposite system with EMS and PEMSDesired reports like, Doff wise, shift wise, count wise, production, energy, UKGSpeed Vs Kw curve, trends, bar graphs, comparisonsAlerts on higher UKG, lesser production, utilization & power fluctuations.Maintenance alerts based on run hours production cost analysis - Cost Audits - Energy Audits
-
FF310 -
General Technologies Corp.
42 V Ready: for use in the new generation of vehicles with mixed or single 42 Volt systems. Operates on DC voltages from 6 to 42 volts. Internally protected against power surges and overloads. 8" flexible probe allows reaching wires in congested places. Transmitter and Receiver LEDs show open or short circuit conditions.
-
bsw TestSystems & Consulting AG
Whether a HF amplifier which is mounted in a 19" rack is viewed as an instrument, a system or a component largely depends on the point of view of the application developer. We list this product family here; however we would like to point out that our 19" amplifiers for rack-mount and benchtop applications, as well as modules without power supply, are listed in the "Components" section.
-
Digitrax, Inc
The LNRP Xtra LocoNet Repeater Module Isolates and Protects LocoNet Layouts, it allows for greater expansion of the LocoNet system on large installations. The LNRP Xtra allows "protected" sections of LocoNet to continue functioning even when a fault occurs elsewhere, the LNRP Xtra automatically reconnects the faulty section once the issue is resolved. Now includes the PS14 power supply.
-
Keysight Technologies
Our broad selection of both bench-friendly and system-ready instruments can meet your testing challenges - from basic to complex - with a wealth of available capabilities.Test confidently with clean, precise DC power that's fully specified and guaranteedSafeguard loads from potential harm with robust output protection and fault detection capabilitiesEnhance system flexibility with built-in, DMM-quality measurement functions
-
HMMC-5026 -
Keysight Technologies
The HMMC-5026 is a broadband GaAs MMIC traveling wave amplifier designed for moderate gain and moderate output power over the full 2-26 GHz frequency range. Typical applications of the HMMC-5026 include wideband gain blocks of communication systems and microwave instrumentation, which require a flat gains response and excellent port matches over the 2-26 GHz frequency range.
-
HMMC-5022 -
Keysight Technologies
The HMMC-5022 is a broadband GaAs MMIC traveling wave amplifier designed for moderate gain and moderate output power over the full 2-22 GHz frequency range. Typical applications of the HMMC-5022 include wideband gain blocks of communication systems and microwave instrumentation, which require a flat gains response and excellent port matches over the 2-22 GHz frequency range.
-
N3300A -
Keysight Technologies
The Keysight N3300A is a full-rack width mainframe with 6-slots that accepts combinations of N330x user-installable load modules (150 W to 600 W) for easy system configuration and future reconfiguration. The N3300A holds up to six N3302A, N3303A, N3304A, N3307A load modules, or three N3305A, N3306A double-wide modules, allowing a total up to 1,800 watts of maximum power.